RANCO ETC-111000-000 Electric Temperature Control 4.5 out of 5 stars 62. Only 2 left in stock - order soon. Johnson Controls A421AEC-02C Electronic Temp. Looking for RANCO Single Pressure Controls, Opens On High/Low Pressure, 40 to 150 Differential Pressure (PSI), SPDT (2E984)? Grainger's got your back. Easy online ordering for the ones who get it done along with 24/7 customer service, free technical support & more.

Introduction: Wiring a RANCO ETC-111000-000 Temperature Controller for Your Kegerator

A lot of homebrewers convert a chest freezer or refrigerator into a kegerator and they plug the fridge or freezer into an external controller to manage temperature. And if you want to go digital there is not a controller better suited for the job than a RANCO ETC-111000-000 controller. RANCO uses a thermistor on the end of a 8' cable to sense temperature & this gives you enough room to mount the controller on the side of your kegerator or on the wall behind your kegerator.
But RANCO ETC-111000-000 controllers to not make good mash controllers! The reason they don't is because they are just smart thermostats and a thermostat is always catching up to its set temperature. For example, let's say for example that you were to set your RANCO ETC-111000-000 up as a mash controller and you set your mash temperature to 145F. If you start at a strike temperature of 135F the RANCO would stay on until the mash temperature at the thermistor read 145F then it would turn off & the mash would cool until the lower trip temperature of 142 is reached & it will turn on, starting the cycle all over again. This cycle would continue and your average mash temperature will be right in the middle - at 143.5F. The correct temperature controller for your mash is a PID controller. A PID controller works to maintain 145F, not catch up with 145F. A PID controller will slightly over-shoot 145F to maintain your set temperature at an average of 145F. And a smart, tuned PID controller can easily maintain your mash to within 1/2 degree F of your set temperature.
Tom - www.kegkits.com

Step 1: Parts Needed

There are a lot of instructions on the net telling you to add a electrical box and outlet to the bottom of your controller. The box and outlet are not needed and only cost you extra money! All you need to wire your RANCO ETC-111000-000 controller are:
1 - RANCO ETC-111000-000 controller
1 - 3 wire extension cord - I chose a 15' extension cord from LOWES because I also wanted to use the cord as a extension cord. You can use a shorter or longer cord.
1 - NM Cable Connector (clamp)
1 - wire nut (not pictured)
Regardless of what cord you buy make sure that it's 3 wire and has both a plug end and a outlet end. You will need to use both ends in this project.

Step 2: Open Your New RANCO Controller

Start by unscrewing the 4 screws and lifting the front off. The front will not separate completely from the back of the controller - a set of wires will hold the two halves together.
lift up the paperboard cover that's inside the bottom and you'll see two terminal strips.
The upper terminal strip will be labeled 240 - 120 - COM. We will be wiring to 120 & COM.
The lower terminal strip will be labeled NC - NO - C.We will be wiring to NO & C.

Step 3: Mount the NM Connector

Unscrew the lock nut from the NM Cable Connector, insert the connector into the bottom of the controller, screw the lock nut back on from the inside & tighten.

Fairfield

Step 4: Cut the Extension Cord Into 2 Pieces

Cut off the outlet end of the extension cord - I made my cut about 1 foot from the end. The exact length is not important as long there is enough cord length left to make the electrical connections inside the controller.

Step 5: Strip Off Outer Covering

Strip off part of the outer covering from the cut-off cord.
Enough covering has to be removed so that the uncovered wires reach from inside of the NM Cable connector to just past the top terminal strip.

Step 6:

Cut the green & black wires back to about 1.5' long.
Save the black wire you cut off! You will use it later.
Strip the ends of all three wires then twist the loose ends together to keep them tight.

Step 7: Insert the Black Wire From the Cord Into the Proper Terminal

Etc

Step 4: Cut the Extension Cord Into 2 Pieces

Cut off the outlet end of the extension cord - I made my cut about 1 foot from the end. The exact length is not important as long there is enough cord length left to make the electrical connections inside the controller.

Step 5: Strip Off Outer Covering

Strip off part of the outer covering from the cut-off cord.
Enough covering has to be removed so that the uncovered wires reach from inside of the NM Cable connector to just past the top terminal strip.

Step 6:

Cut the green & black wires back to about 1.5' long.
Save the black wire you cut off! You will use it later.
Strip the ends of all three wires then twist the loose ends together to keep them tight.

Step 7: Insert the Black Wire From the Cord Into the Proper Terminal

Insert the end through the NM Cable Connector, loosen the bottom terminal strip NO screw, insert the black wire end into the NO terminal and tighten the screw. When tight you should not be able to pull the black wire out of the terminal strip.

Step 8: Check Jumper Length Then Strip Jumper Ends

Bend the black wire you saved earlier into a J shape and compare with the inside of the box to make sure it can connect between the bottom terminal strip C terminal and the top terminal strip 120 terminal.
If the wire is not long enough then you will need to cut a longer section from the remainder of your extension cord and pull out the black wire from the cut-off piece.
Strip the insulation off both ends of your jumper wire. Future krazy but true mp3 download.

Step 9: Strip Covering & Insulation Off the End of Your Remaining Cord

Strip the covering & insulation off the remaining cord. This piece does not need to be stripped back as far as the other end. Twist the ends of the wires together.

Step 10: Wire the Upper Terminal Strip

Feed the cord into the box through the NM Cable Connector. It will be a tight fit and you may need to wiggle the cable a little.
Loosen the top terminal strip C screw, twist the two white wires together, insert the two wires in the C terminal and tighten.
Loosen the top terminal strip 120 screw, twist the two black wires together, insert the two wires in the 120 terminal and tighten.

Step 11: Connect the Ground Wires Together

Twist the two green wires together then twist on a wire nut.
You can see from the bottom picture that I have 2 white wires inserted into the top terminal strip C terminal and 2 black wires inserted into the top terminal strip 120 terminal.

Step 12: Finish the Project

Tighten the two NM Cable Connector screws, put the top back on, tighten the 4 screws and you are done!!!
Thanks, Tom
For more home kegerator & electric home brewery ideas please visit www.kegkits.com

Be the First to Share

Recommendations

33 2.1K
29 1.9K
98 4.0K
1 14 1.6K
  • Holiday Decorations Speed Challenge

  • Plywood Challenge

  • Battery Powered Contest

Automated Aquarium SystemsPresents..
RANCO 'ETC' Series Single and Dual Stage Temperature Controllers

DESCRIPTION:

The Ranco ETC is a microprocessor based electronic temperature controller designed to provide on/off control of heating and cooling (Chillers) . The ETC is equiped with a Liquid Crystal Display(LCD) that provides a constant readout of the sensed temperature, and a touch keypad that allows the user to easily and accurately select the set point temperature, differential set point, and heating or cooling mode of operation. The unit can be operated on either line voltage, 120/208/240VAC. With its wide temperature setpoint range and selectable heating or cooling modes, the ETC can be used for a wide variety of applications such as Research, Science, Laboratory, Education, Aquariums, Hydroponics, Pools and more.

Some of ETC's outstanding features include: Ro2 drop database.

  • Large and easy to read LCD
  • Remote Sensor of up to 400ft away
  • SPDT Output Relay
  • Wide Range: -30 to 220°:F
  • User selctable Fahrenheit/Celcius scales
  • Lockout Switch to prevent tampering by unauthorized personnel
  • Simple 4-step keypad programming

SPECIFICATIONS:

SPECIFICATION ETC-111000
SETPOINT TEMPERATURE RANGE -30°:F to 220°:F
DIFFERENTIAL ADJUSTMENT1°:F to 30°:F
INPUT VOLTAGE120 or 208/240 VAC, 50/60Hz
RELAY SPDT
120VAC, FULL LOAD 16A, 1 HP
208/240VAC, FULL LOAD 8A, 1 HP
SENSORThermistor, 2' long x 0.25' diameter with 8ft. cable
DISPLAYLCD
ENCLOSURE NEMA 1, Plastic
ENVIRONMENT -20 to 140°F; RH 0-95%
DIMENSIONS 175 x 41 x 23mm (7.9 x 1.8 x 1')

HOW TO ORDER:

ETC-111000: Ranco Single-Stage Electronic Temperature Controller (Heat or Cool) with 8ft Sensor and Instructions.. $75.00
ETC-211000: Ranco Dual-Stage Electronic Temperature Controller (Heat AND Cool) with 8ft Sensor and Instructions.. $140.00



RANCO ETC Series Programming Procedures:


Programing procedure for single stage RANCO® ETC series controllers.

Steps

Procedure

Annunciator

Description

Display

Step 1

To start programming, press the SET key once to access the Fahrenheit/Celsius mode. The display will show the current status, either F for degrees Fahrenheit or C for degrees Celsius. Then Press either up or down arrow key to toggle between the F or C Designation.

F or C

Fahrenheit or Celsius Scale

Step 2

Press SET key again to access the setpoint. The LCD will display the current setpoint and S1 annunciator will be blinking on and off to indicate that the controls in the setpoint mode. Then press either the up key to increase or the down key to decrease the set point to the desired setting.

S1 (blinking)

Setpoint Temperature

Vertus fluid mask 3.3.18. Step 3

Press SET key again to access the differential. The LCD will display the current differential and DIF1 annunciator will be blinking on and off to indicate that the controls in the differential mode. Then press either the up key to increase or the down key to decrease the differential to the desired setting.

DIF 1 (blinking)

Differential Temperature

Step 4

Press SET key again to access the cooling or heating mode. The LCD will display the current mode, either C1 for cooling H1 for heating. Then press either the up key or the down key to toggle between the C1 or H1 designation. Press the SET key once more and programming is complete.

C1 / H1

Cooling or Heating mode


Programing procedure for Dual Stage RANCO® ETC series controllers.

Ranco Etc 111-000 Manual


Steps

Procedure

Annunciator

Description

Display

Step 1

To start programming, press the SET key once to access the Fahrenheit/Celsius mode. The display will show the current status, either F for degrees Fahrenheit or C for degrees Celsius. Then Press either up or down arrow key to toggle between the F or C Designation.

F or C

Fahrenheit or Celsius Scale

Step 2

Press SET key again to access the stage 1 setpoint. The LCD will display the current setpoint and S1 annunciator will be blinking on and off to indicate that the controls in the setpoint mode. Then press either the up key to increase or the down key to decrease the set point to the desired setting.

S1 (blinking)

Stage 1 Setpoint Temperature

Step 3

Press SET key again to access the stage 1 differential. The LCD will display the current differential and DIF1 annunciator will be blinking on and off to indicate that the controls in the differential mode. Then press either the up key to increase or the down key to decrease the differential to the desired setting.

DIF 1 (blinking)

Stage 1 Differential Temperature

Step 4

Press SET key again to access the stage 1 cooling or heating mode. The LCD will display the current mode, either C1 for cooling H1 for heating. Then press either the up key or the down key to toggle between the C1 or H1 designation.

C1 / H1

Stage 1 Cooling or Heating mode

Step 5

Press SET key again to access the stage 2 setpoint. The LCD will display the current setpoint and S2 annunciator will be blinking on and off to indicate that the controls in the setpoint mode. Then press either the up key to increase or the down key to decrease the set point to the desired setting.

S2 (blinking)

Stage 2 Setpoint Temperature

Step 6

Press SET key again to access the stage 2 differential. The LCD will display the current differential and DIF2 annunciator will be blinking on and off to indicate that the controls in the differential mode. Then press either the up key to increase or the down key to decrease the differential to the desired setting.

DIF 2 (blinking)

Stage 2 Differential Temperature

Step 7

Press SET key again to access the stage 2 cooling or heating mode. The LCD will display the current mode, either C2 for cooling H2 for heating. Then press either the up key or the down key to toggle between the C2 or H2 designation. Press the SET key once more and programming is complete.

C2 / H2

Stage 2 Cooling or Heating Mode


Troubleshooting error messages

Display

Messages To correct

E1

Appears when either the up or down key is pressed when not in the programming mode If the E1 message appears even when no keys are being pressed, replace control.

E2

Appears if the control settings are not properly stored in memory. Check all settings and correct if necessary.

EP

Appears when the probe is open, shorted or sensing a temperature that is out of range. Check to see if the sensed temperature is out of range. If not, check for probe damage by comparing it to a known ambient temperature between -30°F and 220°F. Replace the probe if necessary.

EE

Appears if the EPROM dada has been corrupted. This condition cannot be field repaired. Replace the control.

CL

Appears if calibration mode has been entered. Remove power to the control for at least five seconds. Reapply power. If the CL message still appeared, replace the control.


How To Place your ORDER

Ranco Etc 111000 Wiring

[HOME | PRODUCTS | HANNA | MILWAUKEE | RO / DI | LAMOTTE | LOVE CONTROLS | DATA ACQUISITION MODULES | MONITORING & CONTROL SYSTEMS | SOFTWARE | TECHNICAL INFO | LINKS | SALES | SERVICE | ABOUT US | NEWSLETTER | CONTACT US]
Automated Aquarium Systems, Inc.
545 South Pacific Street
Tustin, CA 92780 USA
email: sales@automatedaquariums.com
web: http://www.automatedaquariums.com
phone/fax: (714) 669-1196



broken image